References

1. Ahn CB, Kim HH, Cho ZH (1986) High-speed spiral-scan echo planar NMR imaging I. IEEE Trans Med Imaging 5:2

2. Artemov D, Mori N, et al. (2003) Magnetic resonance molecular imaging of the HER-2/neu receptor. Cancer Res 63:2723-2727

3. Bammer R, Schoenberg SO (2004) Current concepts and advances in clinical parallel magnetic resonance imaging. TopMagn Reson Imaging 15:129-158

4. Bhujwalla MZ (2005) Molecular imaging of cancer. Proc Intl Soc Magn Reson Med (in press)

5. Bradley WG (2004) Use of 1024 MRA at 3T enhances neuroscan. Diagn Imaging Eur 10:25-27

6. Buchan A, Barber PA (2004) From bench to bedside: evolving experimental MR imaging technology for cerebral ischemia. ASNR 133 -137

7. Bulte JWM, Brooks RA, et al. (1999) Relaxometry and magnetometry of the MR contrast agent MION-46L. Magn Reson Med 42:379-384

8. Bulte JWM, Duncan ID, et al. (2002) In vivo magnetic resonance tracking of magnetically labelled cells after transplantation. J Cereb Blood Flow Metab 22:899-907

9. Bulte JWM, Zhang S, et al. (1999) Neurotransplantation of magnetically labelled oligodendrocyte progenitors: magnetic resonance tracking of cell migration and myelinati-on. Proc Natl Acad Sci USA 96:15256-15261

10. Bulte JWM, Douglas T, et al. (2001) Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells. Nat Biotechnol 19:1141 -1147

11. Carroll TJ, Korosec FR, et al. (2000) Method for rapidly determining and reconstructing the peak arterial frame from a time-resolved CE-MRA exam. Magn Reson Med 44:817820

12. Carroll TJ, Korosec FR, et al. (2001) Carotid bifurcation: evaluation of time-resolved three-dimensional contrast-enhanced MR angiography. Radiology 220:525-532

13. Carroll TJ, et al. (2002) Time-resolved three dimensional contrast enhanced MR angiography of the peripheral vessels. Radiology 225:43 - 52

14. Dousset V, Delalande C, et al. (1999) In vivo macrophage activity imaging in the central nervous system detected by magnetic resonance. Magn Reson Med 41:329-333

15. Dydak U, Weiger M, et al. (2001) Sensitivity-encoded spectroscopic imaging. Magn Reson Med 46:713-722

16. Dydak U, Pruessmann KP, et al. (2003) Parallel spectro-scopic imaging with spin echo trains. Magn Reson Med 50:196-200

17. Dydak U (2004) Advanced MR spectroscopic imaging techniques. ASNR Proceedings: 182-183

18. Ehman RL, McNamara MT, et al. (1986) Influence ofphysi-ologic motion on the appearance of tissue in MR images. Radiology 159:177-182

19. Flacke S, Fischer S, et al. (2001) Novel MRI contrast agent for molecular imaging of fibrin: implications for detecting vulnerable plaques. Circulation 104:1280-1285

20. Forbes KPN, Pipe JG, et al. (2001) PROPELLER MRI: Clinical testing of a novel technique for quantification and compensation of head motion. J Magn Reson Imaging 14: 215 - 222

21. Gieseke J, Manka C, et al. (2003) Diffusiongewichtete MRT Aufnahmen mit SENSE bei 3 T. Fortschr Roentgenstr 175: 202

22. Glover GH, Pauly JM (1992) Projection reconstruction techniques for reduction of motion effects in MRI. Magn Reson Med 28:275 - 289

23. Grant PE (2004) Structural MR imaging. Epilepsia 45(4): 4-16

24. Griswold MA, Jakob PM, et al. (1999) Resolution enhancement in single-shot imaging using simultaneous acquisition of spatial harmonics (SMASH). Magn Reson Med 41:1236-1245

25. Griswold MA, Jakob PM, et al. (2002) Generalized autocal-ibrating partially parallel acquisition (GRAPPA). Magn Reson Med 47(6):1202 -1210

26. Gupta H, Weissler R (1996) Targeted contrast agents in MR imaging. Magn Reson Imaging Clin N Am 4:171 -184

27. Hany TF, Carroll TJ, et al. (2001) Aorta and runoff vessels: single-injection MR angiography with automated table movement compared with multiinjection time-resolved MR angiography - initial results. Radiology 221:266-272

28. Ho VB, Foo TK (1998) Optimization of gadolinium-enhanced magnetic resonance angiography using an automated bolus-detection algorithm (MR SmartPrep). Invest Radiol 33:515-523

29. Hohen M, Kustermann E, et al. (2002) Monitoring of implanted stem cell migration in vivo: a highly resolved in vivo magnetic resonance imaging investigation of experimental stroke in rat. Proc Natl Acad Sci USA 99:16267-16272

30. Hutchinson M, Raff U (1988) Fast MRI data acquisition using multiple detectors. Magn Reson Med 6(1):87-91

31. Insko EK, Elliott MA, et al. (1998) Generalized reciprocity. J Magn Reson 131:111-117

32. Kim M, Ducros M, et al. (2005) Topography of high-order human object areas measured with DTI and fMRI. Proc Intl Soc Magn Reson Med 13:737

33. Kooi ME, Cappendijk VC, et al. (2003) Accumulation of ultrasmall superparamagnetic particles of iron oxide in human atherosclerotic plaques can be detected by in vivo magnetic resonance imaging. Circulation 107:2453-2458

34. Korosec FR, Frayne R, et al. (1996) Time-resolved contrast enhanced 3D MR angiography. Magn Reson Med 36:345351

35. Kuhl CK (2004) Parallel imaging in neuroradiology. ASNR Proceedings: 181-182

36. Lewin M, Carlesso N, et al. (2000) Tat-peptide-derivatized magnetic nanoparticles allow in vivo tracking and recovery of progenitor cells. Nat Biotechnol 18:410-414

37. Lin C, Bernstein M, et al. (2001) In-vivo and in-vitro measurements of T1 relaxation at 3.0 T. Presented at ISMRM 9th annual meeting, Glasgow, UK, 21-27 April 2001, p 1391

38. Little MW, Mcrobbie DW (2004) Parallel imaging improves scan speed. Diagn Imaging Eur 5:29-35

39. Lowe MJ, Marrie R, et al. (2005) Increased transverse dif-fusivity of water observed in transcallosal motor fiber tracts in multiple sclerosis. Proc Intl Soc Magn Reson Med 13:1056

40. Maki JH, Prince MR (2005) Principles and optimization of contrast-enhanced 3D MR angiography. Syllabus Intl Soc Magn Reson Med 13

41. McKay R (2000) Stem cells: hype or hope? Nature 406:361 -364

42. Morawski AM, Winter PM, et al. (2004) Targeted nanopar-ticles for quantitative imaging of sparse molecular epi-topes with MRI. Magn Reson Med 51:480-486

43. Murphy KJ, Brunberg JA (1997) Adult claustrophobia, anxiety and sedation in MRI. Magn Reson Med 15:51-54

44. Nicolay K, Braun KP, et al. (2001) Diffusion NMR spectroscopy. NMR Biomed 14(2):94- 111

45. Ohlinger MA, Grant AK, et al. (2003) Ultimate intrinsic signal-to-noise ratio for parallel MRI: Electromagnetic field considerations. Magn Reson Med 50:1018-1030

46. Ordidge RJ, Helpern JA, et al. (1994) Correction of motional artifacts in diffusion-weighted MR images using navigator echoes. Magn Reson Med 12:455-460

47. Pathak AP, Gimi B, et al. (2004) Molecular and functional imaging of cancer: advances in MRI and MRS. Methods Enzymol 386:3-60

48. Phillips MD (2005) Functional neuro MRI. Proc Intl Soc Magn Reson Med 13:562

49. Pipe JG (1999) Motion correction with PROPELLER MRI: Application to head motion and free-breathing cardiac imaging. Mag Reson Med 42:963-969

50. Pipe JG (2001) Improved in-plane motion correction for PROPELLER MRI. Proc Intl Soc Magn Reson Med 9:743

51. Pipe JG, Farthing VG, Forbes KP (2002) Multishot diffusion-weighted FSE using PROPELLER MRI. Magn Reson Med 47:42-52

52. Prince MR, Grist TM, et al. (1997) 3D contrast MR angiog-raphy. Springer-Verlag, Berlin

53. Pruessmann KP, Weiger M, et al. (1999) SENSE: sensitivity encoding for fast MRI. Magn Reson Med 42(5):952-962

54. Ra JG, Rim CY (1993) Fast imaging using subencoding data sets from multiple detectors. Magn Reson Med 30(1): 142-145

55. Ramnani N, Beherens TEJ, et al. (2004) New approaches for exploring anatomical and functional connectivity in the human brain. Biol Psychiatry 56:613-619

56. Roemer PB, Edelstein WA, et al. (1990) TheNMRphase array. Magn Reson Med 16(2):192-225

57. Roberts TPL (2004) Clinical magnetic source imaging. ASNR Proceedings: 223

58. Sachs T, Meyer CH, et al. (1995) The diminishing variance algorithm for real-time reduction of motion artifacts in MRI. Magn Reson Med 34:412-422

59. Schultz CL, Alfidi RJ, et al. (1984) The effect of motion on two-dimensional Fourier transformation magnetic resonance images. Radiology 152:117-121

60. Sarty GE (2001) Single trajectory radial (STAR) imaging. Proc Intl Soc Magn Reson Med 9:1806

61. Schiebler ML, Listerud J, et al. (1992) Magnetic resonance angiography of the pelvis and lower extremities: works in progress. Invest Radiol 27:90-96

62. Schmitz SA, Coupland SE, et al. (2000) Superparamagnetic iron oxide-enhanced MRI of arteriosclerotic plaques in Watanabe hereditable hyperlipidemic rabbits. Invest Radiol 35:460-471

63. Schonberg T, Pianka P, et al. (2005) Characterization of displaced white matter tracts using DTI and fMRI. Proc Intl Soc Magn Reson Med 13:468

64. Sipkins DA, Cheresh DA, et al. (1998) Detection oftumour angiogenesis in vivo by v 3-targeted magnetic resonance imaging. Nat Med 4:623 - 626

65. Sipkins DA, Gilbels K, et al. (2000) ICAM-1 expression in autoimmune encephalitis visualized using magnetic resonance imaging. J Neuroimmunol 104:1 -9

66. Sodickson DK, Manning WJ (1999) Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with ra-diofrequency coil arrays. Magn Reson Med42(5):952-962

67. Sodickson DK (2000) Tailored SMASH image reconstruction for robust in vivo parallel MR imaging. Magn Reson Med 44:243-251

68. Storrs RW, Tropper FD, et al. (1995) Paramagnetic polymerised liposomes as new recirculating MR contrast agents. J Magn Reson Imaging 5:719-724

69. Tang C, Friedman J, et al. (2005) Correlations between diffusion tensor imaging (DTI) and magnetic resonance spectroscopy (1HMRS) in schizophrenic patients andnor-mal controls. Proc Intl Soc Magn Reson Med 13:1384

70. Upadhyay J, Lindgren KA, et al. (2005) Function and connectivity in human auditory cortex: A combined fMRI and DTI study at 3T. Proc Intl Soc Magn Reson Med 13:1467

71. Upadhyay J, Kim D-S, et al. (2005) Characterization of intracellular diffusion properties with diffusion tensor spec-troscopy. Proc Intl Soc Magn Reson Med 13:582

72. Van Hoe L, De Jaegere T, et al. (2000) Breath-hold contrast-enhanced three-dimensional MR angiography of the abdomen: Time-resolved imaging versus single-phase imaging. Radiology 214:149-156

73. Vigen KK, Peters DC, et al. (2000) Undersampled projection-reconstruction imaging for time-resolved contrast-enhanced imaging. Magn Reson Med 43:170-175

74. Wang J, Kluge T, et al. (2001) Parallel acquisition techniques with modified SENSE reconstruction mSENSE. Presented at the First Würzburg Workshop on Parallel Imaging, Würzburg, Germany, 7-10 November 2001, p 92

75. Weinmann HJ, Ebert W, et al. (2003) Tissue-specific MR contrast agents. Eur J Radiol 46:33-44

76. Weissleder R (1999) Molecular imaging: exploring the next frontier. Radiology 212:609-614

77. Willinek WA (2004) 3 T systems display rich clinical promise. Diagn Imaging Eur 4:29-33

78. Winter PM, Caruthers SD, et al. (2005) Molecular imaging of vascular targets. Proc Intl Soc Magn Reson Med (in press)

79. Zhu Y, Hardy CJ, et al. (2004) Highly parallel volumetric imaging with a 32-element RF coil array. Magn Reson Med 52:869-877

Was this article helpful?

0 0
10 Ways To Fight Off Cancer

10 Ways To Fight Off Cancer

Learning About 10 Ways Fight Off Cancer Can Have Amazing Benefits For Your Life The Best Tips On How To Keep This Killer At Bay Discovering that you or a loved one has cancer can be utterly terrifying. All the same, once you comprehend the causes of cancer and learn how to reverse those causes, you or your loved one may have more than a fighting chance of beating out cancer.

Get My Free Ebook


Post a comment