References

1. Halperin, H.R., Tsitlik, J.E., Gelfand, M., et al. (1993) A preliminary study of cardiopulmonary resuscitation by circumferential compression of the chest with use of a pneumatic vest. N Engl J Med. 329, 762-768.

2. Cohen, T.J., Goldner, B.G., Maccaro, P.C., et al. (1993) A comparison of active compression-decompression cardiopulmonary resuscitation with standard cardiopulmonary resuscitation for cardiac arrests occurring in the hospital. N Engl J Med. 329, 1918-1921.

3. Arntz, H.R., Agrawal, R., Richter, H., et al. (2001) Phased chest and abdominal compression-decompression versus conventional cardiopulmonary resuscitation in out-of-hospital cardiac arrest. Circulation. 104, 768-772.

4. Tang, W., Weil, M.H., Schock, R.B., et al. (1997) Phased chest and abdominal compression-decompression. A new option for cardiopulmonary resuscitation. Circulation. 95, 1335-1340.

5. Kern, K.B., Hilwig, R.W., Berg, R.A., Schock, R.B., and Ewy, G.A. (2002) Optimizing ventilation in conjunction with phased chest and abdominal compression-decompression (Lifestick) resuscitation. Resuscitation. 52, 91-100.

6. Plaisance, P., Lurie, K.G., Vicaut, E., et al. (1999) A comparison of standard cardiopulmonary resuscitation and active compression-decompression resuscitation for out-of-hospital cardiac arrest. French Active Compression-Decompression Cardiopulmonary Resuscitation Study Group. N Engl J Med. 341, 569-575.

7. Wenzel, V., Lindner, K.H., Prengel, A.W., and Strohmenger, H.U. (2000) Effect of phased chest and abdominal compression-decompression cardiopulmonary resuscitation on myocardial and cerebral blood flow in pigs. Crit Care Med. 28, 1107-1112.

8. Voelckel, W.G., Lurie, K.G., Sweeney, M., et al. (2002) Effects of active compression-decompression cardiopulmonary resuscitation with the inspiratory threshold valve in a young porcine model of cardiac arrest. Pediatr Res. 51, 523-527.

9. Lurie, K.G., Zielinski, T., McKnite, S., Aufderheide, T., and Voelckel, W. (2002) Use of an inspiratory impedance valve improves neurologically intact survival in a porcine model of ventricular fibrillation. Circulation. 105, 124-129.

10. Wolcke, B.B., Mauer, D.K., Schoefmann, M.F., et al. (2003) Comparison of standard cardiopulmonary resuscitation versus the combination of active compression-decompression cardiopulmonary resuscitation and an inspiratory impedance threshold device for out-of-hospital cardiac arrest. Circulation. 108, 2201-2205.

11. Lurie, K.G., Voelckel, W.G., Zielinski, T., et al. (2001) Improving standard cardiopulmonary resuscitation with an inspiratory impedance threshold valve in a porcine model of cardiac arrest. Anesth Analg. 93, 649-655.

12. Cohn, J.N., Ferrari, R., Sharpe, N., and International Forum on Cardiac Remodelling. (2000) Cardiac remodeling—concepts and clinical implications: a consensus paper from an international forum on cardiac remodeling. J Am Coll Cardiol. 35, 569-582.

13. Anversa, P., Olivetti, G., and Capasso, J.M. (1991) Cellular basis of ventricular remodeling after myocardial infarction. Am J Cardiol. 68, 7D-16D.

14. Saaverda, W.F., Tunin, R.S., Paolocci, N., et al. (2002) Reverse remodeling and enhanced adrenergic reserve from passive external support in experimental dilated heart failure. J Am Coll Cardiol. 39, 2069-2076.

15. Francis, G.S. (2001) Pathophysiology of chronic heart failure. Am J Med. 110(Suppl 7A), 37S-46S.

16. Fried, N.M., Tsitlik, A., Rent, K., et al. (2001) Laser ablation of the pulmonary veins using a fiberoptic balloon catheter: implications for treatment of paroxysmal atrial fibrillation. Lasers Surg Med. 28, 197-203.

17. Marrouche, N. and Natale, A. (2002) Monitoring pulmonary vein isolation using phased array intracardiac echocardiography in a patient with atrial fibrillation. Appl Cardiac Imag. November, 19-22.

18. Haissaguerre, M., Jais, P., Shah, D.C., et al. (1998) Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins. N Engl J Med. 339, 659-666.

19. Hill, A.J., McHenry, B.A., Laske, T.G., et al. (2003) Validation of real-time 3D intracardiac echocardiography using Visible Heart™ methodologies. J Card Fail. 9, S51.

20. Gründeman, P.F., Verlaan, C. W., van Boven, W.J., and Borst, C. (2004) Ninety-degree anterior cardiac displacement in off-pump coronary bypass grafting: the Starfish cardiac positioner preserves stroke volume and arterial pressure. Ann Thorac Surg. 78, 679-684.

21. Zaidi, A., Crampton, S., Clough, P., Scheepers, B., and Fitzpatrick, A. (1999) Misdiagnosis of epilepsy. Many seizure-like episodes have a cardiovascular cause [abstract]. Pace. 22(Pt. II), 814.

22. Chinchoy, E., Soule, C.L., Houlton, A.J., et al. (2000) Isolated four-chamber working swine heart model. Ann Thorac Surg. 70, 1607-1614.

Essentials of Human Physiology

Essentials of Human Physiology

This ebook provides an introductory explanation of the workings of the human body, with an effort to draw connections between the body systems and explain their interdependencies. A framework for the book is homeostasis and how the body maintains balance within each system. This is intended as a first introduction to physiology for a college-level course.

Get My Free Ebook


Post a comment