Bibliography

[1] Knutsson, H., Representing local structure using tensors, In: Proceedings of 6th Scandinavian Conference on Image Analysis, 1989, pp. 244251.

[2] Westin, C.-F., A Tensor Framework for Multidimensional Signal Processings, Ph.D. Thesis No. 348, Linkoping University, Sweden, 1994.

[3] Koller, T . M., Gerig, G., Szekely, G., and Dettwiler, D., Multiscale detection of curvilinear structures in 2-D and 3-D image data, In: Proceedings of Fifth International Conference on Computer Vision, 1995, pp. 864869.

[4] Aylward, S., Bullitt, E., Pizer, S., and Eberly, D., Intensity ridge and widths for tubular object segmentation and description, In: Proceedings of IEEE Workshop on Mathematical Methods in Biomedical Image Analysis, 1996, pp. 131-138.

[5] Sato, Y., Nakajima, S., Atsumi, H., Koller, T., Gerig, G., Yoshida, S., and Kikinis, K., 3D multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, In: Lecture Notes in Computer Science, Vol. 1205, pp. 213-222, 1997. Proceedings of CVRMed-MRCAS'97, Glenoble, France.

[6] Lorenz, C., Carlsen, I.-C., Buzug, T. M., Fassnacht, C., and Wesse, J., Multi-scale line segmentation with automatic estimation of width, contrast and tangential direction in 2D and 3D medical images, In: Lecture Notes in Computer Science, Vol. 1205, pp. 233-242, 1997. Proceedings of CVRMed-MRCAS'97, Glenoble, France.

[7] Sato, Y., Nakajima, S., Shiraga, N., Atsumi, H., Yoshida, S., Koller, T., Guido, G., and Kikinis, R., Three-dimensional multi-scale line filter for segmentation and visualization of curvilinear structures in medical images, Med. Image Anal., Vol. 2, No. 2, pp. 143-168, 1998.

[8] Frangi, A., Niessen, W., Vincken, K., and Viergever, M., Multiscale vessel enhancement filtering, Vol. 1426 In: Proceedings of MICCAI'98, Boston, Massachusetts, 1998, pp. 130-137.

[9] Westin, C.-F., Warfield, S., Bhalerao, A., Mui, L., Richolt, J., and Kikinis, R., Tensor controlled local structure enhancement of CT images for bone segmentation, In: Lecture Notes in Computer Science, Vol. 1426, pp. 1205-1212, 1998. Proceedings of MICCAI'98, Boston, Massachusetts.

[10] Sato, Y., Kubota T., Nakanishi K., Sugano N., Nishii T., Ohzono K., Nakamura H., Ochi O., and Tamura S., Three-dimensional reconstruction and quantification of hip joint cartilages from magnetic resonance images, In: Lecture Notes in Computer Science, Vol. 1679, pp. 338-347, 1999. Proceedings of MICCAI'99, Cambridge, UK.

[11] Sato, Y., Westin, C.-F., Bhalerao, A., Nakajima, S., Shiraga, N., Tamura, S., and Kikinis, R., Tissue classification based on 3D local intensity structures for volume rendering, IEEE Trans. Visual. Comput. Graphics, Vol. 6, No. 2, pp. 160-180, 2000.

[12] Sato, Y. and Tamura S., Detection and quantification of line and sheet structures in 3-D images, In: Lecture Notes in Computer Sceinece, Vol. 1935, pp. 164-165, 2000. Proceedings of MICCAI 2000, Pittsburgh, Pennsylvania.

[13] Aylward, S. R. and Bullitt, E., Initialization, noise, singularities, and scale in height ridge traversal for tubular object centerline extraction, IEEE Trans. Med. Imaging, Vol. 21, No. 2, pp. 61-75, 2002.

[14] Suri, J. S., Liu, K., Reden L., and Laxminarayan, S. N., White and black blood volumetric angiographic filtering: Ellipsoidal scale-space approach, IEEE Trans. Inform. Tech. Biomed., Vol. 6, No. 2, pp. 142-158, 2002.

[15] Suri, J. S., Liu, K., Reden L., and Laxminarayan, S. N., A review on MR vascular image processing algorithms: Acquisition and prefiltering, Part I, IEEE Trans. Inform. Tech. Biomed., Vol. 6, No. 4, pp. 324-337, 2002.

[16] Suri, J. S., Liu, K., Reden L., and Laxminarayan, S. N., A review on MR vascular image processing algorithms: Skeleton versus nonskeleton approaches, Part I, IEEE Trans. Inform. Tech. Biomed., Vol. 6, No. 4, pp. 338-350, 2002.

[17] Sato, Y., Nakanishi, K., Tanaka, H., Nishii, T., Sugano, N., Nakamura, H., Ochi, T., and Tamura, S., Limits to the accuracy of 3D thickness measurement in magnetic resonance images, In: Lecture Notes in Computer Science, Vol. 2208, pp. 803-810,2001. Proceedings of MICCAI2001, Utrecht, The Netherlands.

[18] Sato, Y., Tanaka, H., Nishii, T., Nakanishi, K., Sugano, N., Kubota, T., Nakamura, H., Yoshikawa, H., Ochi, T., and Tamura, S., Limits on the accuracy of 3D thickness measurement in magnetic resonance images— Effects of voxel anisotropy, IEEE Trans. Med. Imaging, Vol. 22, No. 9, pp. 1076-1088, 2003.

[19] Haralick, R. M., Watson, L. T., and Laffey, T. J., The topographic primal sketch, Int. J. Robotic Res., Vol. 2, No. 1, pp. 50-72, 1983.

[20] Marr, D., Vision—A Computational Investigation into the Human Representation and Processing of Visual Information, W. H. Freeman, New York, 1982.

[21] Lindeberg, T., On scale selection for differential operators, Proc. 8th Scandinavian Conference on Image Analysis, pp. 857-866, 1993.

[22] Lindeberg, T., Feature detection with automatic scale selection, Int. J. Comput. Vision, Vol. 30, No. 2, pp. 77-116, 1998.

[23] Lindeberg, T., Edge Detection and ridge detection with Automatic Scale Selection, Int. J. Comput. Vision, Vol. 30, No. 2, pp. 117-154, 1998.

[24] Hylton, N. M., Simovsky, I., Li, A. J., and Hale, J . D., Impact of section doubling on MR angiography, Radiology, Vol. 185, No. 3, pp. 899-902, 1992.

[25] Du, Y. P., Parker, D. L., Davis, W. L., and Cao, G., Reduction of partial-volume artifacts with zero-filled interpolation in three-dimensional MR angiography, J. Magn. Reson. Imaging, Vol. 4, No. 5, pp. 733-741, 1995.

[26] Kikinis, R., Gleason, P. L., Moriarty, T. M., Moore, M. R., Alexander, E., III, Stieg, P. E., Matsumae, M., Lorensen, W. E., Cline, H. E., Black, P. M., Jolesz, F. A., Computer-assisted interactive three-dimensional planning for neurosurgical procedures, Neurosurgery, Vol. 38, No. 4, pp. 640-651, 1996.

[27] Nakajima, S., Atsumi, H., Kikinis, R., Moriarty, T. M., Metcalf, D. C., Jolesz, F. A., and Black, P. M., Use of cortical surface vessel registration for image-guided neurosurgery, Neurosurgery, Vol. 40, No. 6, pp. 12011210, 1997.

[28] Levoy, M., Display of surfaces from volume data, IEEE Comput. Graphics Appl., Vol. 8, No. 3, pp. 29-37, 1988.

[29] Lacroute, P. and Levoy M., Fast volume rendering using a shear-warp factorization of the viewing transform, In: Proceedings of SIG-GRAPH'94, 1994, pp. 451-458.

[30] Vandarbrug, S. J., Semilinear line detectors, Comput. Graphics Image Process., Vol. 4, pp. 287-293, 1975.

[31] Burt, P. J. and AdelsonE. H., The Laplacian pyramid as a compact image code, IEEE Trans. Commun., Vol. 31, No. 4, pp. 532-540, 1983.

[32] Shiraga, N., Sato, Y., Kohda, E., Okada, Y., Sato, K., Hasebe, T., Hira-matsu, K., Kikinis, R., and Jolesz, F. A., Three dimensional display of the osteosclerotic lesion by volume rendering method, Nippon Acta Radiol. Vol. 58, No. 2, p. S84, 1998.

[33] Shimizu, A., Hasegawa, J., and Toriwaki J., Minimum directional difference filter for extraction of circumscribed shadows in chest X-ray images and its characteristics, IEICE Trans., Vol. J-76D-II, No. 2, pp. 241249, 1993.

[34] Giger, M. L., Bae, K. T., and MacMahon, H., Computerized detection of pulmonary nodules in computed tomography images, Invest. Radiol., Vol. 24, No. 4, pp. 459-465, 1994.

[35] Kanazawa, K., Kubo, M., Niki, N., Satoh, H., Ohmatsu, H., Eguchi, K., and Moriyama, N., Computer aided screening system for lung cancer based on helical CT images, In: Lecture Notes in Computer Science, Vol. 1131, pp. 223-228,1996. Proceedings of Visualization in Biomedical Computing, Hamburg, Germany.

[36] Steger, C., An unbiased detector of curvilinear structures, IEEE Trans. Patt. Anal. Machine Intell., Vol. 20, No. 2, pp. 113-125, 1998.

[37] Nakanishi, N., Tanaka, H., Nishii, T., Masuhara, K., Narumi, Y., and Nakamura, H., MR evaluation of the articular cartilage of the femoral head during traction, Acta Radiol., Vol. 40, No. 1, pp. 60-63, 1999.

[38] Nakanishi, K., Tanaka, H., Sugano, N., Sato, Y., Ueguchi, T., Kubota, T., Tamura, S., and Nakamura, H., MR-based three-dimensional presentation of cartilage thickness in the femoral head, Euro. Radiol., Vol. 11, No. 11, pp. 2178-2183, 2001.

[39] Parker, D. L., Du, Y. P., and Davis, W. L., The voxel sensitivity function in Fourier transform imaging: applications to magnetic resonance angiography, Magn. Reson. Med., Vol. 33, No. 2, pp. 156-162, 1995.

[40] Hoogeveen, R. M., Bakker, C. J. G., and Viergever, M. A., Limits to the accuracy of vessel diameter measurement in MR angiography, J. Magn. Reson. Imaging, Vol. 8, No. 6, pp. 1228-1235, 1998.

[41] Steckner, M. C., Drost, D. J., and Prato, F. S., Computing the modulation transfer function of a magnetic resonance imager, Med. Phy., Vol. 21, No. 3, pp. 483-489, 1994.

[42] Canny, J., A computational approach to edge detection, IEEE Trans. Patt. Anal. Machine Intell., Vol. 8, No. 6, pp. 679-698, 1986.

0 0

Post a comment